Laboratorial rotameters ROS type

The rotameters ROS are used to measurement of volume fluxes or mass of gases in experimental and laboratorial installations. The rotameters can be produced with scale or with graph of flow for another gases. It is possible to produce this rotameters with control valve.

Exemplary measuring ranges

Accuracy of reading

The standard accuracy class is 2,5 according with PN-85/M-42371. On demand there is possible to execute the rotameter in higher accuracy class with calibration certificate from our laboratory, Weights and Measures Office or from Accredited Laboratory.

Recalculations

Changing the application of rotameters or factor’s parameters require of using the correction coefficient. Correct value of mass or volume flux we are received by multiplying the value from scale (graph) by the correction coefficient. This coefficient depends on kind of measuring factor and units of measurement.

Construction materials

Basic elements of rotameters are glass pipe and float.
Material of pipe: glass (allay of boron and silicon) in sort simax or termisil.
Float’s material: allay of Al, chrominium-nickel steel sort 1H18N9T, tarflen, PCV.
Seal of glass pipe: rings for suitable factor.
Connections, including hose ends, may be manufactured from the same material than floats.
In standard version it is aluminium. Flanges and pipe are made of carbon steel.
The rotameter’s shield is made from plexiglass.

Installation directions

  1. The rotameter’s stresses and vibrations are not allowed.
  2. For rotameter reading we used the biggest dimension of float. Very often it is the upper edge of float. In reading time the float has to assume a steady position without vertical oscillation. The flux of fluid can not contains the gas bubbles.
  3. Pollutants which flows through the rotameter creating the sediments on measuring elements so it is necessary disassemble the rotameter and flush it by dissolving substances. If the user is not able to clean up the rotameter there is possible to clean the rotamater by manufacturer. The sediments in rotameter causes falsility measurements.
  4. The rotameter should be install in vertical position. The permissible devotion: 1.

Order of rotameters

The necessary information in order:

  1. data of medium which flows through the rotameter: type, name, density, absolute pressure, temperature, viscosity
  2. measuring range and kind of scale execution type: (standard or acid-proof steel) with valve or without valve